Contactors Photovoltaic
deutsch english
 

contactors V-G 16 / V-G 16.2 / V-G 40 / V-G 40.2 for railways

V-G 16:

DC control voltage 24 V / 60 V / 110 V / 220 V

railway applications 0.675 - 1.35 x Un

-50°C ... +55°C

AC-3: 10 A / 380 V

AC-1:  16 A / 380 V

DC-5 110 V: 10 A 3 contact in series

auxiliary contacts 2 no + 2 nc

switching time: 20 ms / 10 ms

VG 16.1: 2 resistors with reduced surface temperature

 

V-G 16.2:

DC control voltage 24 V / 60 V / 110 V

double winding coil, no resistor necessary

low power consumption

but high inrush

fixed polarity A1(left) +

connecting points control voltage are changed

higher switching time: 20 ms / 60 ms

  

 

V-G 40:

DC control voltage 24 V / 60 V / 110 V / 220 V

railway applications 0.675 - 1.35 x Un

-50°C ... +55°C

AC-3: 40 A / 380 V

AC-1:  63 A / 380 V

DC-5 110 V: 25 A 3 contact in series

auxiliary contacts 2 no + 2 nc   or  3 no + 1 nc

switching time: 30 ms / 15 ms

VG 40.1: 2 resistors with reduced surface temperature

 

V-G 40.2:

DC control voltage 24 V / 60 V / 110 V

double winding coil, no resistor necessary

low power consumption

but high inrush current

fixed polarity A1(left) +

connecting points control voltage are changed

higher switching time: 30 ms / 130 ms

CMS Version 2.0 2008   Es ist 1 User online